From highly trained experts in our sales force — who assist with product adoption and support in the field — to a global network of healthcare professionals, we provide support services, training and money-saving programs to ensure the best for you and your patients. Our dedicated team members can answer your questions. We’re here to help. Based on internal report #RE00105221, Comparison testing of the Valleylab™ FT10 and ForceTriad™ generators. The Valleylab™ FT10 energy platform has identical power curves and equivalent power delivery for shared modes to the Valleylab™ FX8 energy platform. Page 2 This manual and the equipment it describes are for use only by qualified medical professionals trained in the particular technique and surgical procedure to be performed. It is intended as a guide for servicing the Valleylab Force EZ™-C Series Electrosurgical Generator only. Page 3: Conventions Used In This Guide. Vsphere 6 keygen. Liquid Spillage (IEC 60601-2-2:2006 Clause 44.3 and IEC 60601-2-2:2009 Clause 201.11.6.3) The ForceTriad Energy Platform is constructed so that liquid spillage in normal use does not wet electrical insulation or other components which when wetted are likely to adversely affect the safety of the equipment. The Force 2 generator, refer to the Service Manual. 7.f Introduction 1 The Force 2 Electrosurgical Generator described in this manual is designed to provide the three most significant electrosurgical effects: cutting, desiccation, and fulguration. Solid state design provides both Monopolar and Bipolar outputs.
- News
Valleylab Force 2 Electrosurgical Unit
DESCRIPTION
Instant Response TechnologyValleylab Force 2 Manual Pdf
Instant Response Trade Technology
Instant Response trade technology provides surgeons with improved performance at lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation, and decreasing the need to “turn up the generator.”
A Smoother Cut Through All Tissue Types
The Force FX trade generator adjusts automatically, responding to tissue changes, maintaining power delivery, and minimizing drag.
Added Safety and Reliability Minimizes Electrosurgical Risks
Capacitive coupling is reduced by 30-50 percent when using Instant Response™ technology. This reduction is achieved by limiting the RMS voltage and the high frequency harmonics. Lower voltage means less neuromuscular stimulation and more precise delivery of energy to reduce collateral damage.
Instant Response trade technology provides surgeons with improved performance at lower power settings, minimizing the risk of tissue damage and neuromuscular stimulation, and decreasing the need to “turn up the generator.”
A Smoother Cut Through All Tissue Types
The Force FX trade generator adjusts automatically, responding to tissue changes, maintaining power delivery, and minimizing drag.
Added Safety and Reliability Minimizes Electrosurgical Risks
Capacitive coupling is reduced by 30-50 percent when using Instant Response™ technology. This reduction is achieved by limiting the RMS voltage and the high frequency harmonics. Lower voltage means less neuromuscular stimulation and more precise delivery of energy to reduce collateral damage.
FORUMSView All (32)
Ask a New Question1Replya month ago | a month agoError code 167 When i activate cut mode after 10 sec it show error 167But in cog mode no error showPlease help me how to fix this errorReply |
-akshay 2 months ago | 2 months agoValleylab force fx HelloI have a valleylab force fx -8c esuThe problem is that the output has become very insanely low like 1/2watt both in cut and coag modes.The HVDC supply has also become very low in cut - 35vdc & 99vdc in coag The sysecon signal is 1volt for cut when kept on 300w & 3.74volt when kept on 120wCan anyone please let me know where exactly is the issue.Machine is not displaying any error codes.Reply |
1Reply6 months ago | 6 months agoPM checklist does anyone have pm procedure, checklist ///Reply |
DOCUMENTS / MANUALSView All
Valleylab Sse2l Service Manual
FEATURES
Microcontroller-based isolated electrosurgical generator, designed for all general purpose surgical procedures. Unit includes: • Instant Response™ technology • Adaptive REM™ system • Isolated output • CEM compatible • Bipolar Current Monitor compatible
SPECIFICATIONS
OutPut Frequency | 470 kHz bipolar |
Height | 11.1 cm |
Length | 43.9 cm |
Weight | 8.1 kg |
Width | 35.6 cm |